Key Advantages
Active Protection
Active safety from cell to system: millisecondfault isolation, three-level overcurrentprotection and dual fire suppression.
ms-level
Response Time
3 level
Overcurrent Protection
Dual
Fire Suppression
- Response Time: ms-level
- Overcurrent Protection: 3 level
- Fire Suppression: Dual
High Output
Built for AlDc peak loads: 4c-10c high-rate discharge, 560kW peak outputper rack, 15-year design life at 25°C.
4C-10C
Discharge C-Rate
560kW
Peak Output per Rack
15 years
Long Design Life
- Discharge C-Rate: 4C-10C
- Peak Output per Rack: 560kW
- Long Design Life: 15 years
Lower TCO
Integrated high-density cabinet: 70%less footprint, 8% higher density and80% lower O&M cost over the lifecycle.
70%
Footprint
+ 8%
Cabinet Density
- 80%
O&M Cost
- Footprint: 70%
- Cabinet Density: + 8%
- O&M Cost: - 80%
Fast Delivery
Modular architecture supports up to 12racks in parallel and 6+ scenarios; packreplacement takes under 5 minutes.
12 racks
Max Parallel Units
≤ 5 min
Pack Replacement
≥ 6
Application Scenarios
- Max Parallel Units: 12 racks
- Pack Replacement: ≤ 5 min
- Application Scenarios: ≥ 6
Specifications
|
|
|
| Item | Specifications |
| Rated Voltage | 512V/614.4V/768V |
| Rated Capacity (25°C, 0.33C) | 102Ah/102Ah/102Ah |
| Rated Energy (25°C, 0.33C) | 52.22kWh/62.66kWh/78.33kW |
| Number of Packs | 10/12/15 |
| Voltage Range | 448~576V/537.6~691.2V/672.0~864V |
| Maximum Output Power | 280 kW/340 kW/420 kW |
| Weight | ≈875kg/≈965kg/≈1100kg |
| Standard Charging Current (25°C) | 102A |
| Recommended Charging Voltage (15 Packs) | 820~840V |
| Cut-off Voltage (15 Packs) | 672V |
| Internal Resistance | <60mΩ |
| Protection Functions | Over-charge, Over-discharge, Over-temperature, Short Circuit Protection |
| Storage Temperature | 0℃~45℃ |
| Operating Temperature | 0°C to 45°C (Recommended: 15°C to 35°C) |
| Relative Humidity | 5%~95% (No Condensation) |
| Operating Altitude | ≤4000m (Derating Required Above 1000m) |
| Material System | LiFePO4 |
| IP Level | IP20 |
| Dimensions (W×D×H) mm | 600*1000*2000mm(RACK)240*737*135mm(PACK) |
| Installation | Front Reserved Space: 800mm, Rear Wall-Mounted Installation |
| Communication Protocol | RS485, CAN, TCP, Dry Contacts, etc. |
| Cycle Life (1C/6C, 25°C) | ≥1000@80%SOH |
| Design Life (25°C) | 15 Years |
| Fire Protection | Pack Level + Rack Level |
| Compatibility | Mainstream UPS and HVDC Solutions |
| Certification Plan | UN38.3,UL9540A,UL1973,IEC62619,IEC62477,AC 156,EN61000-6-2&EN61000-6-4 |
|
|
|
| Item | Specifications |
| Rated Voltage | 512V/614.4V/768V |
| Rated Capacity (25°C, 0.33C) | 85Ah/85Ah/85Ah |
| Rated Energy (25°C, 0.33C) | 43.52kWh/52.22kWh/65.28kWh |
| Number of Packs | 10/12/15 |
| Voltage Range | 448~576V/537.6~691.2V/672.0~864V |
| Maximum Output Power | 370 kW/450 kW/560 kW |
| Weight | ≈875kg/≈965kg/≈1100kg |
| Standard Charging Current (25°C) | 85A |
| Recommended Charging Voltage (15 Packs) | 820~840V |
| Cut-off Voltage (15 Packs) | 672V |
| Internal Resistance | <60mΩ |
| Protection Functions | Over-charge, Over-discharge, Over-temperature, Short Circuit Protection |
| Storage Temperature | 0℃~45℃ |
| Operating Temperature | 0°C to 45°C (Recommended: 15°C to 35°C) |
| Relative Humidity | 5%~95% (No Condensation) |
| Operating Altitude | ≤4000m (Derating Required Above 1000m) |
| Material System | LiFePO4 |
| IP Level | IP20 |
| Dimensions (W×D×H) mm | 600*1000*2000mm(RACK)240*737*135mm(PACK) |
| Installation | Front Reserved Space: 800mm, Rear Wall-Mounted Installation |
| Communication Protocol | RS485, CAN, TCP, Dry Contacts, etc. |
| Cycle Life (1C/6C, 25°C) | ≥1000@80%SOH |
| Design Life (25°C) | 5 Years |
| Fire Protection | Pack Level + Rack Level |
| Compatibility | Mainstream UPS and HVDC Solutions |
| Certification Plan | UN38.3,UL9540A,UL1973,IEC62619,IEC62477,AC 156,EN61000-62&EN61000-6-4 |