125kW PCS
The JKP-125LN-AI is a 125kW bidirectional PCS for C&I integrated storage cabinets. This three-phase, four-wire unit features an AC/DC integrated design embedding the high-voltage box, with built-in disconnect switch, fuses, and contactors. It enables battery charge/discharge, power regulation, and grid dispatch.
Key Advantages
Ultra-Fast Response,
Grid-Forming Support
Millisecond response with virtual synchronous generator control supports high-frequency trading and weak-grid stability.
< 20ms
Charge-Discharge Switching
12 units
Off-grid Parallel Operation
  • Charge-Discharge Switching: < 20ms
  • Off-grid Parallel Operation: 12 units
High Efficiency,
Long-term Returns
SiC devices and three-level topology deliver high efficiency and longlife, lowering the cost per cycle.
> 99%
Peak Efficiency
8,000+ cycles
Cycle Life (≥70% EOL)
  • Peak Efficiency: > 99%
  • Cycle Life (≥70% EOL): 8,000+ cycles
Full Three-phase Control,
Universal Fit
Three-phase four-leg topology resolves phase imbalance and voltage violations,enabling intelligent load dispatch.
100%
Single-phase lmbalance
110%
AC Overload Capability
  • Single-phase lmbalance: 100%
  • AC Overload Capability: 110%
Multi-application,
Diversified Returns
Integrated control logic and communication interfaces deliver three revenue streams from a single unit.
3 modes
Capacity, Energy, Ancillary
VPP
Modbus · CAN · IEC 61850
  • Capacity, Energy, Ancillary: 3 modes
  • Modbus · CAN · IEC 61850: VPP
Specifications
DC Side Parameters
Rated DC Voltage Range 680V – 950V
Max. DC Operating Current 202.2A
AC Side Parameters(On-grid)
Rated AC Input/Output Power 125kVA
Max. AC Input/Output Power 137.5kVA
Max. AC Input/Output Current 198.4A
Rated Grid Voltage 380V / 400V
Grid Voltage Range 323V ‒ 437V / 340V ‒ 460V
Rated Grid Frequency 50/60Hz
Grid Frequency Range 47.5Hz ‒ 52.5Hz
Power Factor 0.99 / -1~1
THDi <2%
AC Side Parameters(Off-grid)
Rated Voltage 400V
Voltage Range 340V ‒ 460V
Voltage THD <3% (linear load)
Rated Frequency 50/60Hz
Unbalanced Load Capability 100% (linear load)
Wiring Configuration Three-phase four-wire
Number of Parallel Units 12
General Data
Max. efficiency 99%
Dimensions (W×D×H) 720×900×265mm
Weight <110kg
Ingress Protection IP65
Cooling Forced air cooling
Operating Temperature ‒30°C ~ +60°C (derating > 55°C)
Operating Humidity 0~100%, without consideration
Opearting Altitude 3000m
Communication Interface RS485 / CAN / Ethernet